8200-M585-O1 Rev D 210 Installation & Technical 58
SETUP AND CALIBRATION, CONT.
Cont1= (Continuous Output Serial Port 1)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
Cont1= YES Cont1= no
Continuous Output No Continuous Output
If Cont1= YES (Continuous Output) is selected, an additional prompt, tYPE1=
will be displayed.
If Cont1= no (No Continuous Output) is selected, proceed to the Weight On
Demand section.
tyPE1= (Continuous 1 Output Format)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = SMA 1 = SB-400 2 = SB-200
3 = Rice Lake IQ355 4 = AnDFV 5 = WI110
6 = Number Only 7 = Toledo Long/Short 8 = SB500 with Traffic Light
9 = Ranger 5000 Format A
If tYPE1=7 (Toledo Long/Short) is selected, an additional prompt, tShort will
be displayed.
tShort= (Toledo Short)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
tShort= YES tShort= no
Toledo Short Output Format Toledo Long Output Format
Sio 2? (Setup Serial Port 2)
Press the ENTER key. The display will change to show the current setting no. To skip
configuring the Sio Port 2 (serial input/output) and proceed to the Sio 3? menu, press
the ENTER key again. To configure the Sio 2, press the numeric key 1/YES (display will
change to YES) and then press the ENTER key.
bAUd2= (Serial Port 2 Baud Rate)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, use the numeric keys to enter a new baud rate for
the serial ports, then press the ENTER key to save it. Allowable values are:
12 = 1200 Baud 24 = 2400 Baud 48 = 4800 Baud
96 = 9600 Baud 14 = 14.4k Baud 19 = 19.2k Baud
28 = 28.8k Baud 38 = 38.4k Baud 57 = 57.6k Baud
76 = 76.8k Baud 11 = 115.2k Baud 23 = 230.4k Baud