8200-M585-O1 Rev D 210 Installation & Technical 59
SETUP AND CALIBRATION, CONT.
Prty2= (Serial Port 2 Parity)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 0, 1, or 2.
0 = NONE (No Parity) 1 = Odd Parity 2 = Even Parity
bitS2= (Serial Port 2 Data Bits)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 7 or 8.
StoP2= (Serial Port 2 Stop Bits)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are: 1 or 2.
Cont2= (Continuous Output Serial Port 2)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
Cont2= YES Cont2= no
Continuous Output No Continuous Output
If Cont2= YES (Continuous Output) is selected, an additional prompt, tYPE2=
will be displayed.
If Cont2= no (No Continuous Output) is selected, proceed to the Weight On
Demand section.
tyPE2= (Continuous 2 Output Format)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys enter the new setting,
then press the ENTER key to save it. Allowable values are:
0 = SMA 1 = SB-400 2 = SB-200
3 = Rice Lake IQ355 4 = AnDFV 5 = WI110
6 = Number Only 7 = Toledo Long/Short 8 = SB500 with Traffic Light
9 = Ranger 5000 Format A
If tYPE2=7 (Toledo Long/Short) is selected, an additional prompt, tShort will
be displayed.
tShort= (Toledo Short)
Press the ENTER key to show the current value. If the setting displayed is acceptable, press
the ENTER key again to save it. Otherwise, using the numeric keys, 0/NO or 1/YES, enter the
new setting, then press the ENTER key to save it.
tShort= YES tShort= no
Toledo Short Output Format Toledo Long Output Format