8200-M585-O1 Rev D 210 Installation & Technical 81
ID STORAGE OPERATION, CONT.
Permanent Identification (ID) Strings, Cont.
To Delete A Permanent ID String
1. With the indicator in normal operations mode, press the key. The display will change
FUnCt=, press the Fn key.
2. Enter up to a 6-digit alphanumeric ID string and press the Fn key.
3. The dELid prompt will be displayed, to delete the ID press the 1/YES key. The ID and its
associated tare, accumulator, and loads will be deleted.
NOTE: To abort the delete operation, press the 0/NO key.
4. If the entered ID does not exist, the notFnd message will be displayed.
To Print A Permanent ID String
1. With the indicator in normal operations mode, press the key. The display will change
FUnCt=, press the Fn key.
2. Enter up to a 6-digit alphanumeric ID string and press the PRINT key.
3. The Prtid prompt will be displayed, to print the ID press the 1/YES key. The ID and its
associated tare, accumulator, and loads will be printed.
NOTE: To abort the print operation, press the 0/NO key.
4. If the entered ID does not exist, the notFnd message will be displayed.
To Delete All Permanent ID Strings
1. With the indicator in normal operations mode, press the key. The display will change
FUnCt=, press the Fn key.
2. At the id= prompt, press the Fn key.
3. The dELALL prompt will be displayed, to delete all of the IDs press the 1/YES key. The
IDs and their associated tare, accumulator, and loads will be deleted.
NOTE: To abort the print operation, press the 0/NO key.
4. The indicator will return to normal operation.
To Print All ID Strings
1. With the indicator in normal operations mode, press the key. The display will change
FUnCt=, press the Fn key.
2. At the id=
prompt, press the PRINT key.
3. The PrtALL prompt will be displayed, to print all of the IDs press the 1/YES key. The
IDs and their associated tare, accumulator, and loads will be printed.
NOTE: To abort the print operation, press the 0/NO key.
4. The indicator will return to normal operation.