6
revision 0 date: 07/19 doc. AG525990
- Wet the sealing surfaces of the lter cartridge
slightly with fuel and screw back on to the lter
head, clockwise.
Tightening torque: 17 Nm - 18 Nm
- Mount drain plug.
Tightening torque: 1.6 Nm ± 0.3 Nm
- Electrical connection.
- Connect cable connections.
- Open the fuel shuto tap and vent the system,
“see venting the fuel system”.
Vent the fuel system
The fuel system is vented via the electric fuel supply
pump. In order to ensure that no error messages are
generated, no attempt should be made to start the
system up whilst venting.
This process is carried out as follows:
- Ignition ON
The electronic fuel supply pump switches on for 20
seconds in order to vent the fuel system and build up
the required fuel pressure.
Wait until the electric fuel supply pump is disconnected
from the control unit.
- Ignition OFF
Repeat the process at least 4 times until the fuel
system is vented.
Satare il sistema di distribuzione del carburante
Accensione attivata
Accensione spenta