4.3. Location
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury
or death.
Disconnect power before routing control wiring.
!
WARNING
All wiring must comply with national, local, and state codes.
4.3.1. Wall Control
The Infinity Touch Control is the command center for the Infinity System. It should
be located where it is easily accessible and visible to the adult homeowner or end
user. For accurate temperature measurement, the following guidelines should be
followed:
The Infinity Touch Control and Remote Room Sensors SHOULD be mounted:
S Approximately 5--ft (1.5 m) from the floor.
S Close to or in a frequently used room, preferably on an inside partitioning wall.
S On a section of wall without pipes or ductwork.
The Infinity Touch Control and Remote Room Sensors SHOULD NOT be
mounted:
S Close to a window, on an outside wall, or next to a door leading to the outside.
S Exposed to direct light or heat from a lamp, sun, fireplace, or other
temperature--radiating objects which could cause a false reading.