EasyManua.ls Logo

Carrier SYSTXCCITN01-A - Check out; Electric Heat; Furnace

Carrier SYSTXCCITN01-A
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
55
6.4. Check out
Touch CHECKOUT to view the equipment installed in the system. Perform
checkout test to make sure each piece of equipment is operating properly.
A13122
6.4.1. Electric Heat
If you have a fan coil with electric heaters, this menu item will allow the heaters to
be exercised. With self--identifying electric heaters, three stages of electric heat are
available to be exercised in any combination. Non--identifying heaters will only
provide one stage of heat. After the selections are made, touch START.
S Low Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
S Medium Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
S High Heat: Selectable from 0 to 120 minutes
d Default = 5 minutes
6.4.2. Furnace
Make sure the furnace is properly installed.

Table of Contents

Related product manuals