6-MAINTENANCE
Enginecoolant
CASECONSTRUCTIONrequirestheuseofafullyformulatedOrganicAcidT echnology(OAT)basedcoolant.CASE
AKCELAACTIFULL™OTEXTENDEDLIFECOOLANTisthereferencegenuineproduct.
NOTICE:useofdifferentcoolantbrandsisnotrecommended.
NOTICE:neveraddSupplementalCoolantAdditives(SCA)whenusingCASEAKCELAACTIFULL™OT
EXTENDEDLIFECOOLANT.
NOTICE:nevermixCASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANTcoolantwithconventional
coolant.MixingOATbasedcoolantwithconventionalcoolantwillreducetheeffectivenessofOATcoolant.
NOTICE:ifonlyconventionalcoolantisavailable,acompletechangeoveroftheuidintothecoolingsystemshallbe
carriedout.
theenginecoolingsystemshallalwaysberelledwithcoolantsolutionmadebymixtureofantifreezeanddistilled
(deionized)water.
NOTICE:neverrellthecoolingsystemwithonlyantifreeze.Neverrellthecoolingsystemwithonlywater.
UsingCASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANT,a50/50mixtureofantifreezeanddistilled
(deionized)watergrantsproperperformanceoftheenginecoolingsystemintheabovementionedoperatingtemper-
aturerangeofthemachine.
CASEAKCELAACTIFULL™OTEXTENDEDLIFECOOLANTisavailableas:
50/50PREMIXEDcoolantsolutionreadyforusage.
CONCENTRATEantifreezetobemixed50/50withdistilled(deionized)water.
NOTICE:ifoperatinginextremewinterclimate,acoolantsolutionmadeby60/40antifreeze/distilled(deionized)water
mixtureshallbeusedinordertograntproperperformanceoftheenginecoolingsystem.
NOTICE:neverusecoolantsolutionwithmorethan60%ofantifreeze.Thisaffectsthecoolingcapacityofthemixture.
WhenthecoolantsolutionispreparedstartingfromtheCONCENTRATEproduct,theantifreezeconcentrationinthe
mixtureofantifreezeanddistilled(deionized)watercanbedeterminedwitharefractometerdesignedtomeasure
ethyleneglycolcontent.
Ifdistilled(deionized)waterisnotavailable,usewaterfordilutionwiththefollowingproperties:
PropertyMaximumlimit
TotalSolids
340ppm
TotalHardness340ppm
Chloride(Cl)
340ppm
Sulfate(SO4)
100ppm
AciditypH5.5to9.0
NOTICE:neverusehardwater,seawaterandsoftenedseawaterthathasbeenconditionedwithsalt.Theminerals
andsaltspresentinpotablewatercancausecorrosionanddepositsresultinginshortenedenginelife.
6-7