EasyManuals Logo

Chore-Tronics 2 Control User Manual

Chore-Tronics 2 Control
115 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #39 background imageLoading...
Page #39 background image
Chore-Tronics® 2 Control Overview of Screens
MT1843B
39
(Management Screen) Feed Tab
To access the Management "Feed" Screen, press the Tab Key under "feed". This
screen will be available if a feed scale is connected to the control. This screen
indicates the total feed consumed in the house and how much feed has been
consumed in a certain period of time (for example, how much feed was consumed in
the house in the previous 5 minutes). If house mortality is being entered into the
control, then the total amount of feed per 1000 birds (or per animal) will also be
displayed.
If it is desired for the control to keep track of the approximate feed bin inventory of
the house, then an amount of feed must be entered in the Feed Delivered line and
Agreed must be answered YES. This will put the amount of feed delivered into the
Bin Inventory line. As the feed scale sends data to the control, the control will
subtract the appropriate amount of feed from the Bin Inventory line. When feed is
delivered again to the feed bin, enter the amount delivered in the Feed Delivered line
and change the Agreed line to YES. This will add the amount of feed delivered to the
Bin Inventory. The amount of Feed Delivered must be entered for every feed delivery
made to the house.
(Management Screen) Relationships Tab
To access the Management "Management" Screen, press the Tab Key under
"manag". Both a drinker line Water Meter and a Feed Scale must be connected to the
Control in order for the Management Screen to appear.
MT1842-080 10/04
1
Figure 47. Management Screen: Feed Tab
MT1842-081 10/04
Figure 48. Management Screen: Relationships Tab
1
2
3
1. Water: Feed relation-This is the amount of
water in gallons (liters) consumed per pound
(kilogram) of feed consumed.
2. Estimated Feed conversion-This is ESTI-
MATED feed conversion of the house. This
requires that and ESTIMATED weight be
entered and that the mortality of the house is
being entered into the control
3. Estimated Weight-The ESTIMATED weight
of the house. Must be entered by the user.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chore-Tronics 2 Control and is the answer not in the manual?

Chore-Tronics 2 Control Specifications

General IconGeneral
BrandChore-Tronics
Model2 Control
CategoryControl Unit
LanguageEnglish