Why do Chore-Tronics Control Unit fans turn on when the mode sensor temperature is at the set point?
- KkwarrenAug 7, 2025
If the fans continue to run even when the mode sensor temperature is at the set point, there are several potential causes: * The fan might be assigned to a timer. If you don't want the timer active, remove it in the "Outputs and Temperatures" screen. * The temperature sensors assigned to operate the fan could be different from the mode sensors. If desired, change the temperature sensor assignments in the Setup-General: Outputs Screen. * The fan's manual switch might be set to the manual “on” position. In that case, put the manual switch in the “automatic” position. * There could be a bad Relay Module/MS Board. If this is the case, replace the Module/Board.