Chore-TronicsĀ® 2 Control Overview of Screens
MT1843B
53
(Setup-Control Screen) Curtain Tab
To access the Setup-Control "Curtain Tab", press the Tab Key below "Curtain".
1. Desired 1st movement- The amount (in inches or centimeters) the main cur-
tain(s) should open when the Control enters the Natural mode from the Power
mode.
2. Desired full movement- The desired full movement of the main curtain(s) while
in Natural mode. This value can not be larger than the Mechanical full open
limit which is entered in the Setup-Control: Calibration screen (Screen 14, Cali-
bration tab).
3. Time between curtain movements- The amount of time (in minutes and sec-
onds) the Control will wait after moving the main curtain(s) before checking to
see if another curtain movement is needed (Natural mode only).
4. Rate of curtain movement- The amount the Control will open or close the main
curtain(s) for every degree that the sensor is away from the average of the "Main
Curtain Range." For additional information please see the Control Operation
Overview section of this manual.
5. Tunnel speed- The speed of the tunnel curtain.
6. Full movement- The movement of the tunnel curtain.
MT1842-051 10/04
Figure 67. Setup-Control Screen: CurtainTab