Remote Operation
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: VOLT:STAT:L1 8 Set voltage of load L1 as 8V.
VOLT:STAT:L1 24V Set voltage of load L1 as 24V.
VOLT:STAT:L1 MAX Set voltage of load L1 as the
maximum value.
VOLT:STAT:L1 MIN Set voltage of load L1 as the minimum
value.
Query Syntax: VOLTage:STATic:L1?[<space><MAX | MIN>]
Return Parameters:<NR2>, [Unit = Volt]
Query Example: VOLT:STAT:L1?
VOLT:STAT:L1? MAX
VOLT:STAT:L1? MIN
VOLTage:STATic:L2
Type: Channel-Specific
Description: Set the static load voltage in constant voltage mode.
Setting Syntax: VOLTage:STATic:L2<space><NRf+>[suffix]
Setting Parameters:Refer to respective specification for valid value range.
Setting Example: VOLT:STAT:L2 8 Set voltage of load L2 as 8V.
VOLT:STAT:L2 24V Set voltage of load L2 as 24V.
VOLT:STAT:L2 MAX Set voltage of load L2 as the
maximum value.
VOLT:STAT:L2 MIN Set voltage of load L2 as the minimum
value.
Query Syntax: VOLTage:STATic:L2?[<space><MAX | MIN>]
Return Parameters: <NR2>, [Unit = Volt]
Query Example: VOLT:STAT:L2?
VOLT:STAT:L2? MAX
VOLT:STAT:L2? MIN
VOLTage:STATic:TYPE
Type: Channel-Specific
Description: Set the execution type in constant voltage mode.
Setting Syntax: VOLTage:STATic:TYPE<space><NRf>
Setting Parameters:<NRf>, CURR/PSU(0), VOLT/PSU(1)
Example: VOLT:STAT:TYPE CURR/PSU
VOLT:STAT:TYPE 1
Query Syntax: VOLTage:STATic:TYPE?
Return Parameters:<CRD>, CURR/PSU, VOLT/PSU
Query Example: VOLT:STAT:TYPE?
VOLTage:STATic:RESponse
Type: Channel-Specific
Description: Set the response speed in constant voltage mode.
Setting Syntax: VOLTage:STATic:RESponose<space><NRf>
Setting Parameters:<NRf>, FAST(0), NORMAL(1), SLOW(2)
Example: VOLT:STAT:RES FAST
VOLT:STAT:RES SLOW
Query Syntax: VOLTage:STATic:RESponse?
Return Parameters:<CRD>, FAST, NORMAL, SLOW
Query Example: VOLT:STAT:RES?