Remote Operation
5-81
5.3.2.17 SYNCHRONOUS Subsystem
:SYNChronous
:CHANnel
SP
<NRF+>
:RUN
:TYPE
SP
OFF / 0
ON / 1
NONE / 0
MASTER / 1
SLAVE / 2
SP
SYNChronous:CHANnel
Type: All Channels
Description: Set the specified channel to T1 & T2 in sync dynamic mode for
parallel loading.
Setting Syntax: SYNChronous:CHANnel<space><NRf+>
Setting Parameters:<NRf+>, 1 ~ 10
Setting Example: SYNC:CHAN 1 Set the specified channel to "1".
SYNC:CHAN MAX Set the specified channel to "10".
SYNC:CHAN MIN Set the specified channel to "1".
SYNChronous:RUN
Type: All Channels
Description: Set all electronic loads to “ON” in sync. parallel run.
Setting Syntax: SYNChronous:RUN<space><NRf>
Setting Parameters:<NRf>, OFF(0), ON(1)
Setting Example: SYNC: RUN ON Set the load to “ON” on sync. parallel.
SYNC: RUN OFF Set the load to “OFF” on sync. parallel.
SYNChronous:TYPE
Type: All Channels
Description: Set the specified mainframe to master or slave for sync. in parallel
run.
Setting Syntax: SYNChronous:TYPE<space><NRf>
Setting Parameters:<NRf>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: SYNC:TYPE MASTER Set the mainframe to master for sync.
in parallel run.
SYNC:TYPE SLAVE Set the mainframe to slave for sync. in
parallel run.
SYNC:TYPE NONE Disables the mainframe to sync.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600 Series and is the answer not in the manual?

Chroma 63600 Series Specifications

General IconGeneral
Series63600
Operating Temperature0°C to 40°C
ModesCC, CV
InterfaceGPIB, USB
ProtectionOCP, OTP, OVP
Voltage Resolution1mV
CoolingForced Air