EasyManua.ls Logo

Chroma 63600 Series - MEASURE Subsystem

Default Icon
258 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Operation
5-67
5.3.2.10 MEASURE Subsystem
:MEASure
:CURRent
:VOLTage
:POWer
?
?
?
:ALLVoltage
:ALLCurrent
:ALLPower
?
?
?
<NR2>
<NR2>
<NR2>
<AARD>
<AADR>
<AARD>
:INPut
SP
?
LOAD / 0
UUT / 1
<CRD>
MEASure:ALLCurrent?
Type: Channel-Independent
Description: Returns the real time current measured at the input of all load
modules. The return value is 0 when the channel does not exist.
Query Syntax: MEASure:ALLCurrent?
Return Parameters:<aard>, [Unit = Ampere]
Query Example: MEAS:ALLC?
Return Example: 0, 0, 0, 0, 5.12, 0, 12, 0
MEASure:ALLPower?
Type: Channel-Independent
Description: Returns the real time power measured at the input of all load
modules. The return value is 0 when the channel does not exist.
Query Syntax: MEASure:ALLPower?
Return Parameters:<aard>, [Unit = Watt]
Query Example: MEAS:ALLP?
Return Example: 0, 0, 0, 0, 5.12, 0, 12, 0

Table of Contents