2-19
Cisco 7600 Series Router Installation Guide
OL-4503-26
Chapter 2 Preparing for Installation
Site Requirements
Table 2-19 lists the power and the heat numbers for miscellaneous modules.
OSM-16OC3-POS-SI, -SL
OC-3 POS, 16-port
5.09 214 267 913 287 981
OSM-16OC3-POS-SI+
OC-3 POS, 16-port
4.83 203 254 868 271 925
OSM-2OC12-ATM-MM, -SI
OC-12 ATM, 2-port
3.61 152 190 649 204 698
OSM-2OC12-ATM-MM+,
-SI+
OC-12 ATM, 2-port
4.00 168 210 717 226 771
OSM-1OC48-POS-SS, -SI, -SL
OC-48 POS, 1-port
4.26 179 223 762 240 819
OSM-1OC48-POS-SS+, -SI+,
-SL+
OC-48 POS, 1-port
3.90 164 205 699 220 752
OSM-12CT3/DS0
Channelized T-3 to DS-0,
12-port
2.80 118 147 502 158 540
OSM-1CHOC12/T1-SI
Channelized OC-12/STM-4 to
DS-0, 1 port
2.80 118 147 502 158 540
OSM-1CHOC12/T3-SI
Channelized OC-12, 1-port
3.76 158 231 789 248 848
OSM-1CHOC48/T3-SS
Channelized OC-48, 1-port
5.76 242 197 672 212 723
OSM-2OC48/1DPT-SS, -SI,
-SL
OC-48 DPT
1
/POS, 2-ports
3.59 151 302 1031 325 1108
OSM-4GE-WAN-GBIC
2
Gigabit Ethernet WAN Services
Module, 4-port
5.07 213 188 644 203 692
OSM-2+4GE-WAN+
Gigabit Ethernet WAN Services
Module, 2+4-port
3.76 158 267 911 287 979
1. DPT = Dynamic Packet Transport
2. GBICs = Gigabit Interface Converters
Table 2-18 Power Requirements and Heat Dissipation—OSMs
Model Number/
Module Type
Module
Current (A)
@ 42 VDC
Module
Power
(Watts)
AC DC
AC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)
DC-Input
Power
(Watts)
Heat Diss.
(BTU/HR)