PS4 (Active)
C9400-PWR-3200AC
PS3 (Active)
C9400-PWR-3200AC
PS2 (Active)
C9400-PWR-3200AC
PS1 (Active)
C9400-PWR-3200AC
PS8 (Standby)
C9400-PWR-3200DC
PS7 (Active)
C9400-PWR-3200DC
PS6 (Active)
C9400-PWR-3200DC
PS5 (Active)
C9400-PWR-3200DC
The switch meets all the required conditions for an n+1 redundant mode with a normal protected state.
• It is in an n+1 redundant mode, because one power supply module is configured as standby.
It also meets all the n+1 redundant mode conditions:
• A mix of AC-input and DC-input power supply modules are installed and all modules are of the
same capacity.
In the same output, see Capacity = 3200 W.
• All installed AC-input power supply modules have an AC-input voltage of 220 VAC (the Capacity
fields for the AC-input modules reflect this.
• It is in a normal protected state, because:
Total standby output power (3200 W) is lesser than total active output power (22400).
and
Total active output power (22400) is greater than the required budgeted power (3505)
Switch# show power
Power Fan States
Supply Model No Type Capacity Status 1 2
------ -------------------- ---- -------- ------------ -----------
PS1 C9400-PWR-3200AC ac 3200 W active good good
PS2 C9400-PWR-3200AC ac 3200 W active good good
PS3 C9400-PWR-3200AC ac 3200 W active good good
PS4 C9400-PWR-3200AC ac 3200 W active good good
PS5 C9400-PWR-3200DC dc 3200 W active good good
PS6 C9400-PWR-3200DC dc 3200 W active good good
PS7 C9400-PWR-3200DC dc 3200 W active good good
PS8 C9400-PWR-3200DC dc 3200 W standby good good
PS Current Configuration Mode : N+1 redundant
PS Current Operating State : Normal protected
PS Slots Configured standby : PS8
Power supplies currently active : 7
Power supplies currently available : 8
Power Summary Maximum
(in Watts) Used Available
------------- ------ ---------
System Power 3505 3505
Inline Power 0 18895
------------- ------ ---------
Total 3505 22400
Other valid configuration options for the n+1 mode:
• All installed modules are AC-input power supply modules of the same capacity and with the same
AC-input voltage voltage level; one module is configured as standby.
System Management Configuration Guide, Cisco IOS XE Bengaluru 17.4.x (Catalyst 9400 Switches)
243
Environmental Monitoring and Power Management
Example: n+1 Redundant Mode (Power Supply Modules of the Same Capacity but Different Types + Normal Protected State