7-12 D9865 Satellite Receiver Installation and Operation Guide 4035197 Rev C
MPE alarm Set Data lost, transport
error
Cause: Transport
error indicator is set
in the transport
stream.
Remedy: Verify
uplink is in good
condition.
Transport error
detected, MPE
data may be lost.
Major
Data lost, CRC error Cause: CRC error
detected in MPE
stream.
Remedy: Verify
uplink is in good
condition.
CRC error
detected in MPE
stream, data is
lost.
Data lost, CC error Cause: CC error
detected in MPE
stream.
Remedy: Verify
uplink is in good
condition.
CC error
detected in MPE
stream, data is
lost.
Data lost, buffer
overflow
Cause: Buffer
overflow detected in
MPE stream.
Remedy: Reduce
MPE rate.
Buffer overflow
detected in MPE
stream, data is
lost.
Data lost, bad
sections
Cause: Bad section
data detected in MPE
stream, due to
original data or
overflow issue.
Remedy: Verify
uplink is in good
condition and/or
reduce MPE rate.
Bad sections
detected while
processing MPE
data, data is lost.
Data lost, MPE
capacity exceeded
Cause: Bit rate
controller dropping
data due to CPU load
limitations.
Remedy: Reduce
MPE rate.
Decoder
exceeded safe
CPU load for
MPE processing,
MPE data is lost.
Alarm Message
Type
Message Cause/Remedy Description Severity