VLAN Management
Regular VLANs
240 Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4
12
- Access VLAN ID—When the port is in Access mode, it will be a member of this
VLAN.
- Multicast TV VLAN—When the port is in Access mode, it will be a member of this
Multicast TV VLAN.
Trunk Mode Membership
- Native VLAN ID—When the port is in Trunk mode, it will be a member of this
VLAN.
- Tagged VLANs—When the port is in Trunk mode, it will be a member of these
VLANs. The following options are possible:
All VLANs—When the port is in Trunk mode, it will be a member of all VLANs.
User Defined—When the port is in Trunk mode, it will be a member of the VLANs
that are entered here.
General Mode Membership
- Untagged VLANs—When the port is in General mode, it will be an untagged
member of this VLAN.
- Tagged VLANs—When the port is in General mode, it will be a tagged member of
these VLAN
- Forbidden VLANs—When the port is in General mode, the interface is not allowed
to join the VLAN even from GVRP registration. When a port is not a member of
any other VLAN, enabling this option on the port makes the port part of internal
VLAN 4095 (a reserved VID)
- General PVID—When the port is in General mode, it will be a member of these
VLANs.
Customer Mode Membership
- Customer VLAN ID—When the port is in Customer mode, it will be a member of
this VLANs.
- Customer Multicast VLANs—When the port is in Customer mode, it will be a
member of this Multicast TV VLANs.
STEP 5 Select a port and click Details to view the following fields:
Administrative VLANs—Port is configured for these VLANs.
Operational VLANs—Port is currently a member of these VLANs.

Table of Contents

Other manuals for Cisco SG350-10MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-10MP and is the answer not in the manual?

Cisco SG350-10MP Specifications

General IconGeneral
ModelSG350-10MP
CategorySwitch
PoE Budget130W
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
Power SupplyInternal
Ports8 x 10/100/1000 PoE+ + 2 x Gigabit SFP
MAC Address Table Size16K
Jumbo Frame Support9216 bytes
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Operating Humidity10% to 90% relative humidity, non-condensing
Storage Humidity5% to 95% relative humidity, non-condensing
Dimensions (W x D x H)279.4 x 170 x 44 mm (11.0 x 6.7 x 1.73 in)

Related product manuals