Security: Secure Sensitive Data Management
SSD Rules
Cisco 350, 350X and 550X Series Managed Switches, Firmware Release 2.4, ver 0.4 367
19
SSD Rules and User Authentication
SSD grants SSD permission only to authenticated and authorized users and according to the
SSD rules. A device depends on its user authentication process to authenticate and authorize
management access. To protect a device and its data including sensitive data and SSD
configurations from unauthorized access, it is recommended that the user authentication
process on a device is secured. To secure the user authentication process, you can use the local
authentication database, as well as secure the communication through external authentication
servers, such as a RADIUS server. The configuration of the secure communication to the
external authentication servers are sensitive data and are protected under SSD.
NOTE The user credential in the local authenticated database is already protected by a non SSD related
mechanism
If a user from a channel issues an action that uses an alternate channel, the device applies the
read permission and default read mode from the SSD rule that match the user credential and
the alternate channel. For example, if a user logs in via a secure channel and starts a TFTP
upload session, the SSD read permission of the user on the insecure channel (TFTP) is applied
Default SSD Rules
The device has the following factory default rules:
The default rules can be modified, but they cannot be deleted. If the SSD default rules have
been changed, they can be restored.
Rule Key Rule Action
User Channel Read Permission Default Read Mode
Level 15 Secure XML
SNMP
Plaintext Only Plaintext
Level 15 Secure Both Encrypted
Level 15 Insecure Both Encrypted
All Insecure XML
SNMP
Exclude Exclude
All Secure Encrypted Only Encrypted
All Insecure Encrypted Only Encrypted

Table of Contents

Other manuals for Cisco SG350-10MP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG350-10MP and is the answer not in the manual?

Cisco SG350-10MP Specifications

General IconGeneral
ModelSG350-10MP
CategorySwitch
PoE Budget130W
Switching Capacity20 Gbps
Forwarding Rate14.88 Mpps
Power SupplyInternal
Ports8 x 10/100/1000 PoE+ + 2 x Gigabit SFP
MAC Address Table Size16K
Jumbo Frame Support9216 bytes
ManagementWeb-based, CLI, SNMP
Operating Temperature0°C to 45°C (32°F to 113°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Operating Humidity10% to 90% relative humidity, non-condensing
Storage Humidity5% to 95% relative humidity, non-condensing
Dimensions (W x D x H)279.4 x 170 x 44 mm (11.0 x 6.7 x 1.73 in)