The Network List
2110 SSB Transceiver Reference Manual 123
Settings in the Network List
Network Name
Scan Network
The Scan Network setting applies to all types of networks. It enables you to specify
whether or not you want the channels in the network to be scanned when scanning is
switched on. You can also set the transceiver to scan for voice in voice networks even
when the Mute Type is set to Selcall mute.
Call System
The Call System setting applies to all types of networks. The call system is the method
used by the network to make and receive calls, for example, Codan Selcall, ALE/CALM
or Voice Only. The call systems from which you can select depend on the options
installed in the transceiver.
If your network uses the Codan Selcall call system, you can make calls by selecting an
appropriate channel/mode then entering the address of the station you want to call. When
your call is detected by the receiving station, that station rings to alert the operator. If
your network uses the ALE/CALM call system the transceiver can select the best
channel/mode for you. If your network uses the Voice Only call system, you can make
calls by selecting an appropriate channel/mode then pressing PTT and speaking. You
cannot enter the address of the station you want to call.
Call Detect Time
The Call Detect Time setting applies to all types of networks. The call detect time is the
length of time the transceiver pauses on each channel, when scanning, to detect an
incoming call. You can set the call detect time to <default> or to a specific value.
NOTE
In the following discussion, you will need to log in as administrator to see
the Network List (see page 110, Logging into admin level from user level).
CAUTION
You should be aware of any restrictions placed on network names in your
transceiver when it is used with InterNav software.
NOTE
The transceiver will scan a maximum of 100 channels at a time. If the
total number of channels in all the networks you are scanning exceeds
100, only 100 of the channels will be scanned.
CAUTION
Any station that is tuned to your frequency and has mute off can listen to
your voice conversation.

Table of Contents

Other manuals for Codan 2110

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Codan 2110 and is the answer not in the manual?

Codan 2110 Specifications

General IconGeneral
BrandCodan
Model2110
CategoryTransceiver
LanguageEnglish

Related product manuals