Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
(by Day)
Sets or returns the Reasl-Time-Clock date in the form ddmmyy, where:
dd=day of the month (01 to 31)
mm=month of the year (01 to 12)
yy=year (00 to 99) (2000 to 2099)
COMMAND EXAMPLE (date=April 25, 2016): <0001/DAY=250416{CR}
DAY?
DAY*
myy
Statistics
Averaging
Enables or Disables averaging of statistics data, at a rate of once per second
every 10 seconds, in the form x, where:
0=Disable (DEFAULT ā SEE NOTE)
1=Enable
NOTE: If Disabled, burst values will be logged instead of averaged values.
COMMAND EXAMPLE: <0001/ESA=0{CR}
ESA?
ESA*
Statistics
Logging
Sets or returns the statistics logging function in the form x, where:
0=Disable (DEFAULT)
1=Enable
COMMAND EXAMPLE: <0001/ESL=1{CR}
ESL?
ESL*
Redundancy
Switch Mode
Sets or returns the redundancy state in the form x, where:
0=Off (DEFAULT)
1=1:1 Redundancy Tx (Only Tx switch installed)
2=1:1 Redundancy Tx + RX (Tx and RX switch installed)
5=1:1 Manual redundancy mode (used for debugging, or redundancy system
setup) (SEE NOTE)
NOTE: Manual redundancy does not support automatic switching, and the offline
unit will not poll the online unit to update its configuration.
COMMAND EXAMPLE: <0001/ESW=1{CR}
ESW?