Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–20 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Number
Sets or returns the fan model number in the form xxx, where:
1=Comair Rotron, 255=ADDA
Default value: 255
Example: <0001/FMN=1{CR} (sets the fan model number to Comair Rotron)
FMN?
Firmware
Number
Returns the Boot, Bulk1, and Bulk2 firmwares loaded into the unit, each firmware
load [a,b,c] is in the form FW-AAAAAAA B.B.BB DD/MM/YY where:
FW-AAAAAAA=the firmware part number
B.B.BB=the version number
DD/MM/YY=Day/Month/Year firmware released
EXAMPLE: <0001/FRW?{CR}
>0001/FRW={CR}
Boot: {CR}
FW-0000082 0.0.1a 04/09/08{CR}
Bulk1: {CR}
FW-0000078 0.0.1a 04/09/08{CR}
FW-0000080 0.0.1a 04/09/08{CR}
FW-0000081 0.0.1a 04/09/08{CR}
Bulk2: {CR}
FW-0000078 0.0.1a 04/09/08{CR}
FW-0000080 0.0.1a 04/09/08{CR}
FW-0000081 0.0.1a 04/09/08{CR}{LF}
:[a]:{CR}Bu
lk1:{CR}[a]{
CR}[b]{CR}
[c]{CR}Bulk
2:{CR}[a]{C
R}[b]{CR}[c
]{CR}{LF}
Configuration
Sets or returns the global status of the LPOD, semicolon delimited, in the form
aa.aa;b;ccccc;d;e;f;g;h;j;k;l;m;n;o where:
a=redundancy mode (ESW)
b=online status (ONL)
cc.cc=Attenuation Offset (AOF)
dd.dd=Customer Attenuation(ATT)
e=Auto Fault Recovery (AFR)
GAC*
GAC?
GAC#