Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–30 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Status
(Cont)
A10V1=OK{CR} (+10V1 RF supply) (SEE NOTE)
A10V2=NA{CR} (+10V2 RF supply) (SEE NOTE)
P7V8T=OK{CR} (+7.8V power supply)
P5V8T=OK{CR} (+5.8V power supply)
P2V5T=OK{CR} (+2.5V power supply)
P1V2T=OK{CR} (-1.2V power supply)
N5V8T=OK{CR} (-5.8V power supply)
FANR1=OK{CR} (Fan 1 speed) (SEE NOTE)
FANR2=OK{CR} (Fan 2 speed) (SEE NOTE)
ATEMP=OK{CR} (Amplifier temperature)
SHTDN=OK{CR} (Over-temp shutdown)
IICST=OK{CR} (I2C bus status)
FWPWR=OK{CR} (Forward power in dBm)
CHKSM=OK{CR} (Flash checksum)
FPGAD=NA{CR} (FPGA done status)
BUCLD=OK{CR} (BUC lock detect) (SEE NOTE)
REFLD=NA{CR} (Reference lock detect) (SEE NOTE)
LNBCS=XXXXX{CR} (LNB current status) (SEE NOTE)
SWITC=NA{CR} (Waveguide switch position status) (SEE NOTE)
RDLNK=NA{CR} (Redundancy link status) (SEE NOTE)
TRMST=YS{CR}{LF} (Terminal Status)
NOTE: LNBVT, A10V1, A10V2, FANR1, FANR2, BUCLD, REFLD, LNBCS,
SWITC and RDLNK only appear in the list if the appropriate model/options have
Soft Reboots the unit in the form x where:
RBT?