Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–31 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Configuration
Status
Returns the configuration status of the unit.
EXAMPLES:
<0001/RCS?{CR}
ATT=12.75{CR}
AMP=1{CR}
MUT=1{CR}
ONL=1{CR}
ESW=1{CR}
AOF=00.00{CR}
AFR=1{CR}
XRF=NA{CR}{LF} (SEE NOTE)
Where:
ATT= attenuation in dB
AMP= RF power amplifier state where 0=OFF, 1=ON
MUT=RF mute state where 0=unmuted, 1=muted
RED=Online status for redundancy
ESW=Redundancy and mode states where 0=OFF, 1=ON Tx only, 2=ON Tx & Rx
AOF=Attenuator Offset in dB
AFR= auto fault recovery where 0=manual, 1=auto
XRF=External reference status where NA=no external reference, 05M=5 MHz,
and 10M=10 MHz
NOTE: XRF will always be NA if the internal reference oscillator option is not
Sets or returns Redundancy Online status in the form x, where:
0=Offline
1=Online
NOTE: This command is functionally identical to the ONL command.
COMMAND EXAMPLE: <0001/RED=1{CR}
RED?
RED*