Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–41 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Controller-to-Target
Instruction Code and
Qualifier
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
Target-to-Controller
(see Description of
Arguments)
Command Query
Response to
Command
Response
to Query
Time Protocol
Enable
TPE=
TPE?
1 byte,
numerical
Command or Query.
Sets or returns Time Protocol in the form x, where:
0=Disable
1=Enable
COMMAND EXAMPLE: <0001/TPE=1{CR} (Enables Time protocol)
TPE=
TPE?
TPE=x
Time Protocol
Server
TPS=
TPS?
15 bytes,
alphanumeric
Command or Query.
Sets or returns the Time Server IP Address for the unit’s Tx Ethernet management
port, in the form xxx.xxx.xxx.xxx.
Default value: 255.255.255.255
COMMAND EXAMPLE: <0001/TPS=192.168.001.005{CR}
TPS=
TPS?
TPS=xx.xx
x.xxx.xxx
Terminal Status
Change
N/A
TSC?
1 byte
Query only.
Indicates if there has been a change in the configuration since the last time the
command was given, in the form x, where:
0=No status change.
1=Status change has occurred.
NOTES:
1) A “status change” is defined as any time a parameter is changed, e.g.,
when a command is successfully executed that changes a value. A status
change also results when there is a fault condition.
2) A query does not set the status change flag. The status change flag is
cleared after being read.
EXAMPLE: <0001/TSC?{CR}
>0001/TSC=0{CR}{LF}
TSC=
TSC=x