Low Power Outdoor (LPOD) Amplifier/Block Up Converter (BUC)
Revision 15
Serial Interface Operation 5–40 MN-LPOD
Parameter
Type
(* indicates
End-of-Life)
Instruction Code and
Arguments
for Command
or Query
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
(see Description of
Command Query
Response to
Command
Response
to Query
Community
characters, no
spaces
Sets or returns the SNMP Write Community string.
COMMAND EXAMPLE: <0001/SWC=private{CR}
NOTE: An empty string is not allowed.
SWC!
Revision
Returns the value of the internal software revision installed in the unit, in the form:
Boot:x.y.z Bulk1:x.y.z Bulk2:x.y.z
-or-
Boot:x.y.zz Bulk1:x.y.zz Bulk2:x.y.zz
:x.y.zz
Bulk1:x.y.z
z
Bulk2:x.y.z
Sets or returns the Real-Time-Clock time in the form hhmmss, where:
hh=hours, from 00 to 23;
mm=minutes, from 00 to 59,
ss=seconds, from 00 to 59
COMMAND EXAMPLE (time=23 hours, 12 minutes and 59 seconds since
midnight – i.e., 11:12:59 PM):
TIM?
TIM *
x
Returns the temperature of the Heatsink in the form sxxxx, where:
s=sign byte, positive or negative (+ or –)
xxxx=temperature (including decimal point)
EXAMPLE: <0001/TMP?{CR}
x
Number of
Unread Stored
Alarms*
Returns the number of stored events that remain unread in the alarm log in the
form xx, where:
xx=number from 00 to 99.
NOTE: Although a maximum of 255 events may be stored in the alarm log, event
tallies greater than 99 are reported as 99.
EXAMPLE: <0001/TNA?{CR}