EasyManua.ls Logo

CONCH HM Series - Contact Type & Range; Settings of Communication Parameters: (According to Linked Device)

Default Icon
152 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
133
HM Series Connection Manual
6.24.2. Contact Type & Range:
Contact Type
Code Format
Numbering Range of Address
Block
Input Relay
Xn
n = 0~777 (Octal system)
Multiples of 10
Output Relay
Yn
n = 0~777 (Octal system)
Multiples of 10
Auxiliary Relay
Mn
n = 0~5119
Multiples of 8
ST1 Status
Sn
n = 0~999
Multiples of 8
Special Relay
Mn
n = 9000~9255
Multiples of 8
Timer Relay
Tn
n = 0~255
Counter Relay
Cn
n = 0~255
Timer Coil
TCn
n = 0~255
Counter Coil
CCn
n = 0~255
6.24.3. Settings of Communication Parameters:
(According to Linked Device)
Parameters
Default Value
Setting Range
Device Address
0
0 ~ 255
Communication Mode
RS232
RS232 / RS485 / RS422
Baud Rate
19200 bps
4800 bps ~ 38400 bps
Data Length
7 bits
Parity Check
Even
Stop Bit
1 bit
Command Delay Time
0
0 ~ 1000 ms
HMI Address