Menu 22
Parameter
structure
Keypad and
display
Parameter x.00
Parameter description
format
Advanced parameter
descriptions
Serial comms
protocol
Performance
198 Mentor MP Advanced User Guide
www.controltechniques.com Issue Number: 4
5.21 Menu 22: Additional menu 0 setup
Menu 22 contains parameters that are used to set up the source parameters for the first 20 parameters in Menu 0.
These parameters define the parameters that reside in the programmable area in menu 0.
22.01 to 22.20 Parameter 00.xy setup
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
21111
Range Pr 0.00 to Pr 22.99
Default 0.00
Update rate Background read