Menu 5
Parameter
structure
Keypad and
display
Parameter x.00
Parameter
description format
Advanced parameter
descriptions
Serial comms
protocol
Performance
96 Mentor MP Advanced User Guide
www.controltechniques.com Issue Number: 4
This parameter allows the flux feedback to come from an external field current controller (not FXMP25). This can be done via either an analog input
or by a high speed fieldbus. When Pr 5.48 is set to 1 this parameter is used as the flux feedback.
5.89
External flux feedback
Coding
BitSP FI DETEVMDPNDRANCNVPTUSRWBUPS
11 1 11
Range
0 to 100.0 %
Update rate
1 ms read