6-18
Copyright 2017 Cummins Inc.
ALTERNATOR
LIFTING EYE
LOCATION
MOUNTING FEET
BRACKET
FIGURE 6-11. P7 LIFTING POSITION
19. Using an adequate lifting device, lift the alter-
nator (at lifting eyes provided, and main stator
housing) until the mounting feet brackets are
clear of the frame member (see Figure 6-12 or
6-13).
20. Disconnect the grounding strap from the fly-
wheel housing.
21. Using a forklift, position a lifting bar of the forklift
(inside and inline with the alternator) under the
rotor shaft. Lift the rotor shaft slightly so that ro-
tor is not resting on inside of stator assembly.
See Figure 6-12 or 6-13.