5-17
Copyright 2017 Cummins Inc.
the customer fault message to be changed, Cus-
tomer Fault 2, 3 or 4.Press the upper-left button by
the display to select the desired character.
Press the upper-right button to move the cursor to
the next character to be changed. (Holding this but-
ton down will return the cursor to the first position.)
The message can be up to 16 characters. The fault
code number will remain the same, this code cannot
be edited.
If these messages are changed, you should note
these changes in the Troubleshooting section of the
Operator’s manual for this generator set.
SAVE/EXIT submenu: From the LANGUAGE sub-
menu, press the button next to the “>>” in the dis-
play to move to the SAVE/EXIT submenu. Select
SAVE to save your changes. At the CHANGES
SAVED submenu, select EXIT to return to the DIS-
PLAYS/METERS submenu.
If you select SAVE, the adjustments will be retained
after shutdown, and will be in effect when the set is
restarted. If you select EXIT without saving first, the
adjustments will remain in effect until the generator
set is shut down, but will be reset (and will not be in
effect) when the set is restarted.