Curtis 1222 Manual, os 15
59
2 9 J A N U A R Y 2 0 1 3 D R A F T
4a — MONITOR MENU: Command Input
Monitor Menu: COMMAND INPUT Analog Input
DISPLAY
VARIABLE RANGE DESCRIPTION
Analog 1 0 10.00 V The voltage measured at the Command
0x4413 0x00 0 1023 Analog 1 input (pin 8).
Analog 3 0 10.00 V The voltage measured at the Command
0x4414 0x00 0 1023 Analog 3 input (pin 19).
Angle (deg)
-2880.0 2880.0 This variable is used by both the Sin/Cos
0x44BC 0x00 -32768 32767 and Sawtooth sensor inputs.
In Absolute Position mode, Angle (deg) =
Angle Raw (deg) minus the Center Angle (deg)
parameter.
In Relative Position mode, Angle (deg)
= Angle Raw (deg) minus the relative center
angle (which is recalculated each time the
interlock is enabled).
Angle 2 (deg)
-2880.0 2880.0 This variable is used by both the Sin/Cos
0x44BD 0x00 -32768 32767 and Sawtooth sensor inputs.
In Absolute Position mode, Angle 2 (deg)
= Angle Raw 2 (deg) minus the Center Angle
(deg) parameter.
In Relative Position mode, Angle 2 (deg)
= Angle Raw 2 (deg) minus the relative center
angle (which is recalculated each time the
interlock is enabled).
Angle Raw (deg)
-2880.0 2880.0 This variable is used by both the Sin/Cos
0x44BE 0x00 -32768 32767 and Sawtooth sensor inputs. It is calculated
from the sensor input voltages (pins 8 and 19).
Angle Raw 2 (deg)
-2880.0 2880.0 This variable is used by both the Sin/Cos
0x44BF 0x00 -32768 32767 and Sawtooth sensor inputs. It is calculated
from the sensor input voltages (pins 8 and 19).