52
Curtis 1298 Manual, OS 11
3 — PROGRAMMABLE PARAMETERS: Hydraulic Parameters
HYDRAULICS MENU, cont’d
ALLOWABLE
PARAMETER RANGE DESCRIPTION
Lift BDI Lockout On/Off When programmed On, this parameter enables a check of the
Lift_BDI_Lockout On/Off BDI_Percentage variable. When BDI_Percentage falls to 0%,
OptionBits4 [Bit 0] the Pump BDI fault is set and pump operation is locked out starting
with the next pump operation.
Hyd Inhibit Type (HPD)
0–3 The hydraulic inhibit function prohibits lift or lowering operation if the
Hyd_Inhibit_Type 0–3 hydraulic throttle request is greater than 25% within 250 msec of KSI
being turned on.
The following types of hydraulic inhibit can be set:
0 = Hydraulic inhibit disabled.
1 = Hydraulic inhibit enabled for lift (pump) operation
and disabled for lowering operation.
2 = Hydraulic inhibit enabled for lowering operation
and disabled for lift (pump) operation.
3 = Hydraulic inhibit enabled for both lift (pump)
and lowering operation.