You should start at 1472 and work your way down by 10 each time. Once you get a reply, go up by 2 until you get a fragmented packet. Take that
value and add 28 to the value to account for the various TCP/IP headers. For example, lets say that 1452 was the proper value, the actual MTU size
would be 1480, which is the optimum for the network were working with (1452+28=1480).
Once you nd your MTU, you can now congure your router with the proper MTU size.
To change the MTU rate on your router follow the steps below:
• Open your browser, enter the IP address of your router (192.168.1.1) and click OK.
• Enter your username (admin) and password (sometimes blank by default). Click OK to enter the web conguration page for the device.
• Click on Setup and then click Manual Congure.
To change the MTU, enter the number in the MTU eld and click Save Settings to save your settings.
Test your email. If changing the MTU does not resolve the problem, continue changing the MTU in increments of ten.

Table of Contents

Other manuals for D-Link DSL-2740M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link DSL-2740M and is the answer not in the manual?

D-Link DSL-2740M Specifications

Ports & Interfaces IconPorts & Interfaces
RJ-11 ADSL port1
RJ-45 Ethernet ports4
Wireless InterfaceIEEE 802.11n/g/b
Wireless Specifications IconWireless Specifications
Wireless Bandwidth Rate IEEE 802.11b11, 5.5, 2, and 1 Mbps
Wireless Bandwidth Rate IEEE 802.11g54, 48, 36, 24, 18, 12, 9, and 6 Mbps
Wireless Bandwidth Rate IEEE 802.11n 20 MHz150, 130, 117, 104, 78, 52, 39, 26, 13 Mbps
Wireless Bandwidth Rate IEEE 802.11n 40 MHz300, 270, 243, 216, 162, 108, 81, 54, 27 Mbps
Operating Environment IconOperating Environment
Operating Humidity0% to 90% non-condensing
Non-Operating Humidity5% to 95% non-condensing
Operating Temperature0 to 40 °C (32 to 104 °F)
Non-Operating Temperature-20 to 65 °C (-4 to 149 °F)
Power IconPower
Input Voltage100~240 V AC (±20%), 50/60 Hz
Output Voltage12 V DC
Output Current0.5 A
Weight and Dimensions IconWeight and Dimensions
Dimensions160 x 120 x 25 mm (6.30 x 4.72 x 0.98 inches)
Weight205 grams (7.2 ounces)