xStack® DES-3200 Series Layer 2 Ethernet Managed Switch CLI Reference Manual
40
1
config loopdetect trap
Used to co
nfigure loopback detection traps.
Purpose
config lo
opdetect trap [ none | loop_detected | loop_cleared | both ]
Syntax
This
command is used to specify the trap modes for loop detection.
Description
none – A trap
is not sent in either case.
Parameters
loop_detected - Trap is sent when the loop condition is detected.
loop_cleared - Trap is sent when the loop condition is cleared.
both – A trap is sent in either case.
Only Administrator-level users
can issue this command.
Restrictions
Example usage:
To set trap mode for loopback detection:
DES-3200-28F:4# config loopdetect trap both
Command: config loopdetect trap both
Success.
DES-3200-28F:4#