xStack® DES-3200 Series Layer 2 Ethernet Managed Switch CLI Reference Manual
92
Exam
ple usage:
To create a syslog host:
DES-3200-28:4#create syslog host 1 ipaddress 10.68.88.1 severity all facility
local0
Command: create syslog host 1 ipaddress 10.68.88.1 severity all facility
local0
Success.
DES-3200-28:4#
config syslog
Used to co
nfigure the syslog protocol to send system log data to a remote
host.
Purpose
config
syslog {host [all |<index 1-4>]} {severity [informational | warning | all] |
facility [local0 | local1 | local2 | local3 | local4 | local5 | local6 | local7] |
udp_port <udp_port_number> | ipaddress [<ipaddr>] | state [enable |
disable] }
Syntax
This
command is used to configure the syslog protocol to send system log
information to a remote host.
Description
all – This is to specify all available indexes.
<index 1-4> Specifies that the command will be applied to an index of
hosts. There are four available indexes, numbered 1 through 4.
severity Severity level indicator. These are described in the following:
Bold font indicates that the corresponding severity level is currently
supported on the Switch.
Parameters
Numerical Severity
Cod
e
0 Emergency: system is unusable
1 Alert: action must be taken immediately
2 Critical: critical conditions
3 Error: error conditions
4 Warning: warning conditions
5 Notice: normal but significant condition
6 Informational: informational messages
7 Debug: debug-level messages
informatio
nal Specifies that informational messages will be sent to the
remote host. This corresponds to number 6 from the list above.
warning Specifies that warning messages will be sent to the remote host.
This corresponds to number 4 from the list above.
all Specifies that all of the currently supported syslog messages that are
generated by the Switch will be sent to the remote host.
facility Some of the operating system daemons and processes have been
assigned Facility values. Processes and daemons that have not been
explicitly assigned a Facility may use any of the "local use" facilities or they
may use the "user-level" Facility. Those Facilities that have been designated
are shown in the following: Bold font indicates the facility values the Switch
currently supports.