9 | Electrical installation
Installer reference guide
125
ERLA11~16D + EBBH/X11+16D
Daikin Altherma 3 R W
4P643603-1B – 2022.05
Item Description
Remote outdoor sensor See:
Installation manual of the remote outdoor
sensor
Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=1 (External sensor = Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
Remote indoor sensor See:
Installation manual of the remote indoor
sensor
Addendum book for optional equipment
Wires: 2×0.75mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
Human Comfort Interface See:
Installation and operation manual of the
Human Comfort Interface
Addendum book for optional equipment
Wires: 2×(0.75~1.25mm²)
Maximum length: 500m
[2.9] Control
[1.6] Room sensor offset
(in case of DHW tank)
3‑way valve
See:
Installation manual of the 3-way valve
Addendum book for optional equipment
Wires: 3×0.75mm²
Maximum running current: 100mA
[9.2] Domestic hot water
(in case of DHW tank)
Domestic hot water tank
thermistor
See:
Installation manual of the domestic hot
water tank
Addendum book for optional equipment
Wires: 2
The thermistor and connection wire (12m)
are delivered with the domestic hot water
tank.
[9.2] Domestic hot water