4/13
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
5.7.2 [2-00] R/W 0: Each day
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
7: Sunda
y
5.7.3 [2-02] R/W 0~23 hour, step: 1 hour
1
5.7.4 [2-03] R/W [E-07]1
:
55~75°C, step: 5°C
60°C
[E-07]=1
:
60°C
60°C
5.7.5 [2-04] R/W [E-07]1:
5~60 min, step: 5 min
40 min
[E-07]=1:
40~60 min, step: 5 min
40 min
Tank
5.8 [6-0E] R/W [E-07]=0 or 7 (*3):
40~60°C, step: 1°C
60°C
[E-07]=1 (*4):
40~65°C, step: 1°C
60°C
[E-07]=3 or 8 (*3):
40~75°C, step: 1°C
75°C
[E-07]=5 (*3):
40~80°C, step: 1°C
80
°
C
5.9 [6-00] R/W 2~40°C, step: 1°C
8°C
5.A [6-08] R/W
2~20°C, step: 1°C
10°C
5.B R/W
0: Fixed
1: Weather de
p
endent
└─ WD curve
5.C [0-0B] R/W
35~[6-0E]°C, step: 1°C
50°C
5.C [0-0C] R/W 45~[6-0E]°C, step: 1°C
55°C
5.C [0-0D] R/W 10~25°C, step: 1°C
15°C
5.C [0-0E] R/W -40~5°C, step: 1°C
-10°C
Tank
5.D [6-01] R/W
0~10°C, step: 1°C
0°C
User settings
└─ Quiet
7.4.1 R/W
0: OFF
1: Manual
2: Automatic
7.4.3 R/W
0: Quiet
1: More Quiet
2: Most Quiet
└─ Electricity price
7.5.1 R/W 0,00~990/kWh
1/kWh
7.5.2 R/W 0,00~990/kWh
1/kWh
7.5.3 R/W 0,00~990/kWh
1/kWh
User settings
7.6 R/W 0,00~990/kWh
0,00~290/MBtu
1,0/kWh
Installer settings
└─ Configuration wizard
└─ System
9.1.3.2 [E-03] R/O
3: 6V (*1)
4: 9W
(
*2
)
9.1.3.3 [E-05]
[E-06]
[E-07]
R/W (*3)
R/O (*4)
No DHW (*3)
EKHW, small volume (*3)
Integrated (*4)
EKHW, big volume (*3)
EKHWP (*3)
3rd party, small coil (*3)
3rd
p
art
y,
bi
g
coil
(
*3
)
9.1.3.4 [4-06] R/W 0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
9.1.3.5 [7-02] R/W
0: Single zone
1: Dual zone
9.1.3.6 [E-0D] R/O
0: No
1: Yes
9.1.3.7 [6-02] R/W 0~10kW, step: 0,2kW
3kW (*3)
0kW
(
*4
)
9.1.3.8 [C-02] R/W
0: No
1: Bivalent throu
g
h header
9.1.3.9 [D-07] [E-07]=5
R/W (*4)
0: No
1: Yes
└─ Backup heater
Operation day
Start time
Tank setpoint
Duration
Maximum
Hysteresis
Hysteresis
Setpoint mode
Leaving water value for high ambient temp. for DHW WD curve.
Leaving water value for low ambient temp. for DHW WD curve.
High ambient temp. for DHW WD curve.
Low ambient temp. for DHW WD curve.
Margin
Activation
High
Medium
Level
Low
Gas price
BUH type
Domestic hot water
Emergency
Number of zones
Glycol filled system
BSH capacity (*3)
Bivalent
Solar
4P655201-1 - 2021.09
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*

Table of Contents

Other manuals for Daikin Altherma 3 R W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Altherma 3 R W and is the answer not in the manual?

Daikin Altherma 3 R W Specifications

General IconGeneral
TypeAir-to-water heat pump
RefrigerantR-32
Energy Efficiency Class (Heating)A+++
Energy Efficiency Class (Cooling)A++
Operating Temperature Range (Heating)-25°C to 35°C
Operating Temperature Range (Cooling)10°C to 46°C
Heating Capacity4.0 - 16.0 kW
Sound Power Level62 dBA

Related product manuals