EasyManua.ls Logo

Daikin Altherma 3 R W - Page 307

Daikin Altherma 3 R W
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5/13
Breadcrumb Field code Setting name Range, step
Default value
Date Value
Field settings table
Installer setting at variance with
default value
9.1.4.1 [5-0D] R/W (*1)
R/O (*2)
0: 230V, 1~ (*1)
1: 230V, 3~ (*1)
2: 400V
,
3~
(
*2
)
9.1.4.2 [4-0A] R/W 0: 1
1: 1/1+2
2: 1/2
3: 1/2 + 1/1+2 in emer
g
enc
y
9.1.4.3 [6-03] R/W 0~10kW, step: 0,2kW
2kW (*1)
3kW
(
*2
)
9.1.4.4 [6-04] R/W 0~10kW, step: 0,2kW
4kW (*1)
6kW
(
*2
)
└─ Main zone
9.1.5.1 [2-0C] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.5.2 [C-07] R/W
0: LWT control
1: Ext RT control
2: RT control
9.1.5.3 R/W 0: Fixed
1: WD heating, fixed cooling
2: Weather de
p
endent
9.1.5.4 R/W
0: No
1: Yes
9.1.5.5 R/W 0: 2-points
1: Slo
p
e-Offset
9.1.6 [1-00] R/W -40~5°C, step: 1°C
-10°C
9.1.6 [1-01] R/W 10~25°C, step: 1°C
15°C
9.1.6 [1-02] R/W [9-01]~[9-00], step: 1°C
[2-0C]=0:
40°C
[2-0C]=1:
45°C
[2-0C]=2:
55°C
9.1.6 [1-03] R/W [9-01]~min(45, [9-00])°C, step: 1°C
25°C
9.1.7 [1-06] R/W 10~25°C, step: 1°C
20°C
9.1.7 [1-07] R/W
25~43°C, step: 1°C
35°C
9.1.7 [1-08] R/W [9-03]~[9-02]°C, step: 1°C
22°C
9.1.7 [1-09] R/W [9-03]~[9-02]°C, step: 1°C
[2-0C]=0:
18°C
[2-0C]=1:
5°C
[2-0C]=2:
18°C
└─ Additional zone
9.1.8.1 [2-0D] R/W 0: Underfloor heating
1: Fancoil unit
2: Radiator
9.1.8.3 R/W 0: Fixed
1: WD heating, fixed cooling
2: Weather de
p
endent
9.1.8.4 R/W
0: No
1: Yes
9.1.9 [0-00] R/W [9-05]~min(45,[9-06])°C, step: 1°C
25°C
9.1.9 [0-01] R/W [9-05]~[9-06], step: 1°C
[2-0D]=0:
40°C
[2-0D]=1:
45°C
[2-0D]=2:
55°C
9.1.9 [0-02] R/W 10~25°C, step: 1°C
15°C
9.1.9 [0-03] R/W -40~5°C, step: 1°C
-10°C
9.1.A [0-04] R/W [9-07]~[9-08]°C, step: 1°C
[2-0D]=0:
18°C
[2-0D]=1:
5°C
[2-0D]=2:
18°C
9.1.A [0-05] R/W [9-07]~[9-08]°C, step: 1°C
22°C
9.1.A [0-06] R/W 25~43°C, step: 1°C
35°C
9.1.A [0-07] R/W 10~25°C, step: 1°C
20°C
└─ Tank
9.1.B.1 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
9.1.B.2 [6-0A] R/W 30~[6-0E]°C, step: 1°C
55°C
9.1.B.3 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.4 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
9.1.B.6 [6-08] R/W
2~20°C, step: 1°C
10°C
└─ Domestic hot water
Voltage
Configuration
Capacity step 1
Additional capacity step 2
Emitter type
Control
Setpoint mode
Schedule
Low ambient temp. for LWT main zone heating WD curve.
High ambient temp. for LWT main zone heating WD curve.
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
Low ambient temp. for LWT main zone cooling WD curve.
High ambient temp. for LWT main zone cooling WD curve.
Leaving water value for low ambient temp. for LWT main zone cooling WD curve.
Leaving water value for high ambient temp. for LWT main zone cooling WD curve.
Emitter type
Setpoint mode
Schedule
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
High ambient temp. for LWT add zone heating WD curve.
Low ambient temp. for LWT add zone heating WD curve.
Leaving water value for high ambient temp. for LWT add zone cooling WD curve.
Leaving water value for low ambient temp. for LWT add zone cooling WD curve.
High ambient temp. for LWT add zone cooling WD curve.
Low ambient temp. for LWT add zone cooling WD curve.
Heat up mode
Comfort setpoint
Eco setpoint
Reheat setpoint
WD curve type
Reheat hysteresis
(*1) *6V_(*2) *9W_(*3) EBB*_(*4) EBV*_
(*5) *X*_(*6) *H*_(*7) *11*_(*8) *16*_
(*9) *SU*_(*10) *18*_(*11) *23*
4P655201-1 - 2021.09

Table of Contents

Other manuals for Daikin Altherma 3 R W

Related product manuals