EasyManua.ls Logo

Dalsa Linea SWIR GigE Series - Figure 4: PRNU Derating Curve

Dalsa Linea SWIR GigE Series
136 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Linea SWIR GigE Series Camera Linea SWIR GigE Series Overview
13
PRNU Derating Curve
The sensor profile shape changes as it approaches the maximum line rate for a given exposure
time. For best PRNU performance, the camera flat field calibration should be calibrated at the
target line rate and exposure time.
Figure 4: PRNU Derating Curve
-1.00%
-0.50%
0.00%
0.50%
1.00%
1.50%
2.00%
2.50%
3.00%
0 5000 10000 15000 20000 25000 30000 35000 40000
Change in response/uniformity (%)
Line Rate (Lines/second)
Change in PRNU vs Line Rate
Pixel Response Non-Uniformity
Mean Change in Response