Linea SWIR GigE Series Camera Operational Reference
35
Internal Programmable Exposure
The Linea SWIR GigE camera in the Internal Programmable Exposure mode has the following
features:
The Trigger Source feature (see I/O Control category) selects an internal signal as trigger.
The programmable internal trigger maximum line rate limit is related to the ExposureTime
feature.
Exposure duration is user programmable (exposure maximum is dependent on the line rate).
Minimum exposure (in µs) is model dependent.
External Programmable Exposure
The External Programmable Exposure mode is similar to Internal Programmable except the
exposure start being an external user input.
The Trigger Source feature (see I/O Control category) selects an external signal line as trigger.
Line rate and exposure limits are defined by Internal Programmable Exposure.
Exposure Delay Constraints
Exposure maximum delay specified by the user should not exceed the period of the signal.
If the exposure trigger is edge rather than level, the delay should not exceed half the period.
If these parameters are violated, the camera ignores new transitions / pulses / triggers until
the specified delay has passed.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dalsa Linea SWIR GigE Series and is the answer not in the manual?

Dalsa Linea SWIR GigE Series Specifications

General IconGeneral
BrandDalsa
ModelLinea SWIR GigE Series
CategoryDigital Camera
LanguageEnglish

Related product manuals