8-50 Coasting Select
Option: Function:
[0] Digital input
[1] Bus
[2] Logic AND
[3]
*
Logic OR
Select control of the coasting function via the terminals (digital
input) and/or via the bus.
NB!
This parameter is active only when par. 8-01
Control Site
is set to [0]
Digital and
control word
.
8-51 Quick Stop Select
Option: Function:
[0] Digital input
[1] Bus
[2] Logic AND
[3]
*
Logic OR Select control of the Quick Stop function via the terminals (dig-
ital input) and/or via the bus.
NB!
This parameter is active only when par. 8-01
Con-
trol Site
is set to [0]
Digital and control word
.
8-52 DC Brake Select
Option: Function:
[0] Digital input
[1] Bus
[2] Logic AND
[3]
*
Logic OR
Select control of the DC brake via the terminals (digital input)
and/or via the fieldbus.
NB!
This parameter is active only when par. 8-01
Control Site
is set to [0]
Digital and
control word
.
8-53 Start Select
Option: Function:
[0] Digital input
2. How to Programme FC 300 Programming Guide
132
MG.33.M2.02 - VLT
®
is a registered Danfoss trademark
2