24. Re-installtheIGVonthecompressorandfinger-tightenthefasteners.
25. Tightenthefastenersinacrisscrosspatternto22Nm(16ft.lb.).
Figure 4-70 IGV Housing Installation
26. Leaktestandevacuatecompressorinaccordancewithstandardindustrypractices.
27. PlugintheFeedthroughandSuctionPressureTemperatureSensorHarness.
28. TorquetheremainingFeedthroughfastener(theonesecuringtheMotorHarnessRetainerClip)to5
Nm(44in.lb.).
29. Returnthecompressorbacktonormaloperation.
30. TestrunthecompressortoverifyproperoperationandmovementoftheIGVassembly.RefertoFigure
4-71IGVPositionIndicatortoverifythepositionoftheIGV.
NOTE
AllIGVassembliesarefullyopenwhenthePositionIndicatorBallisattheOPENposition.
Figure 4-71 IGV Position Indicator
Page 94 of 294 - M-SV-001-EN Rev. H 1/23/2023