Figure 4-135 AC Input Ring and DC Spade Connector Removal - TTS/TGS/TTH/TGH Rev. H (Except TTS300/TGS230)
4. RemovetheDC-DCConnections.
a. IftheDC-DCisthepottedstyle,removeconnectorsJ1andJ4.RefertoFigure4-131DC-DC
Connectors(Potted)onpage135.
b. IftheDC-DCistheopen-framestyle,onlyJ1willneedtoberemoved.RefertoFigure4-130DC-DC
Connectors(OpenFrame)onpage134.
5. RemovetheSoftStartAC/DCHarnessfromtheSoftStart.
a. ForcompressorswiththeClosed-TopSoftStart,removetheJ1andJ7(ifequipped)connector.
RefertoFigure4-132Closed-TopSoftStartJ1andJ7Removalonpage135.
NOTE
CompressorsutilizingtheopenframeDC-DCdesigndonotutilizetheJ7:TriggerSignalconnector.
b. ForcompressorswiththeOpen-TopSoftStart,removeconnectorsJ1andJ8.RefertoFigure4-133
Open-TopSoftStartJ1andJ8Removalonpage136.
6. Removetheharness.
4.17.2.3 Soft Start AC/DC Harness Installation - TTS300/TGS230
NOTE
ForTTS300/TGS230Compressors,itmaybehelpfultoremovetheSoftStartand/ortheOpen-FrameDC-DCtogainbetteraccessforthis
procedure.
1. Placethewiringharnessontopofthecompressor.RefertoFigure4-136SoftStartAC/DCHarness
Position-TTS300/TGS230onpage138forthisandthenextfive(5)steps.
M-SV-001-EN Rev. H-1/23/2023 Page 137 of 294