EasyManuals Logo

Danfoss TTS700 User Manual

Danfoss TTS700
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #167 background imageLoading...
Page #167 background image
Figure 4-178 Soft Start Cable Harness to DC Bus
4.21.2 DC Bus Voltage Verification
UsetheDCBusTestHarnesstodetermineifDCbusvoltageiswithinthecorrectrangefortheapplication.Referto
Section1.10DCBusTestHarnessInstallationandRemovalonpage25.
4.21.2.1 Bleed Resistor Verification
NOTE
ThisverificationstepdoesnotapplyiftheDCCapacitorBusBarAssemblycontainstheBalanceBoard.
1. IsolatethecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22ofthismanual.
2. Disconnectthebleedresistorfromonesideofthecapacitor.
3. BendthebleedresistorbackslightlyuntilitnolongercontactstheDCbus.
CAUTION
AfaultybleedresistorcanbetheresultofafaultyDCcapacitor.
4. Usingamultimetersetforresistancemeasurement,placetheleadsoneachofthebleedresistor
terminals.Themeasuredvalueshouldbebetween24.3kΩand29.7kΩforTTS300/TGS230compressors
orbetween16.2kΩand19.8kΩforTTS350,TTS400,TTS450,TTS500,TTS700,TGS310,TGS380,TGS390,
TGS520,TTH375,andTGH375compressors.
4.21.2.2 Snubber Capacitor Verification
1. IsolatethecompressorpowerasdescribedinSection1.8ElectricalIsolationonpage22.
2. RemovetheSoftStart.RefertoSection4.14SoftStartonpage113.
M-SV-001-EN Rev. H-1/23/2023 Page 167 of 294

Table of Contents

Other manuals for Danfoss TTS700

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss TTS700 and is the answer not in the manual?

Danfoss TTS700 Specifications

General IconGeneral
BrandDanfoss
ModelTTS700
CategoryAir Compressor
LanguageEnglish

Related product manuals