AHF version
AHF
enclosure
size
AHF terminal connections
500–690 V
50 Hz
Terminals X1 and X2 Terminals X3 and X4 Terminals A and B PE
AHF
005
AHF
010
Cable
cross-
sections
[mm
2
(AWG/
MCM)]
Termina-
tion
Torque
[Nm (in-
lb)]
Cable
cross-
sections
[mm
2
(AWG(M
CM)]
Termina-
tion
Torque
[Nm (in-
lb)]
Cable
cross-
sections
[mm
2
(AWG/
MCM)]
Termina-
tion
Torque
[Nm (in-
lb)]
Type
Torque
[Nm (in-
lb)]
[A] [A] Type
15
20
24
15
20
24
X3
1.5–25
(16–4)
Cable
end
sleeve
3.5 (31)
±10%
1.5–16
(16–6)
Cable
end
sleeve
2.4 (21.2)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M8
10 (88.5)
±10%
29
36
29
36
X4
1.5–50
(16–
1-1/0)
Cable
end
sleeve
4 (35.4)
±10%
1.5–25
(16–4)
Cable
end
sleeve
3.5 (31)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M8
10 (88.5)
±10%
50
58
50
58
X5
10–70
(8–2/0)
Cable
end
sleeve
5 (44.3)
±10%
1.5–25
(16–4)
Cable
end
sleeve
3.5 (31)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M8
10 (88.5)
±10%
77
87
109
128
77
87
109
128
X6
2.5–95
(14–3/0)
Cable lug
M8
10 (88.5)
±10%
1.5–50
(16–
1-1/0)
Cable
end
sleeve
4 (35.4)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M8
10 (88.5)
±10%
155
197
155
197
240
X7
25–300
(4–600)
Cable lug
M16
50
(442.5)
±10%
16–150
(6–300)
Cable
end
sleeve
18
(159.3)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M12
40 (354)
±10%
240
296
296
366
395
X8
25–300
(4–600)
Cable lug
M16
50
(442.5)
±10%
16–150
(6–300)
Cable
end
sleeve
18
(159.3)
±10%
0.5–4
(20–12)
Cable
end
sleeve
0.8 (7.1)
±10%
M12
40 (354)
±10%
Table 7.6 Terminal Specications, 500–690 V, 50 Hz
7.1.3 Environmental Data
Ambient temperature during operation
5–45 °C (41–113 °F) without derating
5–60 °C (41–140 °F) with derating 1.5% per °C. See Illustration 7.1
Temperature during storage and transpor-
tation
Transport: -25 °C to +65 °C (-13 °F to +149 °F)
Storage: -25 °C to +55 °C (-13 °F to 131 °F)
Maximum altitude above sea level 1000 m (3280 ft) without derating
1000–4000 m (3280–13123 ft) with derating 5% per 1000 m (3280 ft)
Relative humidity Humidity class F without condensation 5–85% - Class 3K3 (non-condensing) during operation
Insulation strength Overvoltage category lll according to EN 61800-5-1
Resonance strength Base standard: DIN EN 600068-2-6
Test specication: 5 Hz, 150 Hz, 3 directions (0.5 g, 0.1 g, 0.5 g)
Sine vibration test Base standard: DIN EN 600068-2-6
Test specication: 5–13.2 Hz, 150 Hz (2 mm (0.08 in) peak to peak 0.7 g)
Packaging DIN 55468 for transport packaging materials
Enclosure protection rating IP00 and IP20
Optional IP21/NEMA1 upgrade kits for IP20 versions
Approvals CE
The Low Voltage Directive
UL
1)
Table 7.7 Environmental Data
1) UL only for 460 V/60 Hz and 600 V/60 Hz versions.