EasyManuals Logo

Danfoss vlt FC 102 Programming Guide

Danfoss vlt FC 102
322 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
13-10 Comparator Operand
Array [6]
Option: Function:
[67] Out of current
range
[68] Below I low
[69] Above I high
[70] Out of speed
range
[71] Below speed
low
[72] Above speed
high
[75] Out of
feedback
range
[76] Below
feedback low
[77] Above
feedback high
[80] Thermal
warning
[82] Mains out of
range
[85] Warning
[86] Alarm (trip)
[87] Alarm (trip
lock)
[90] Bus OK
[91] Torque limit &
stop
[92] Brake fault
(IGBT)
[93] Mech. brake
control
[94] Safe stop
active
[100] Comparator 0
[101] Comparator 1
[102] Comparator 2
[103] Comparator 3
[104] Comparator 4
[105] Comparator 5
[110] Logic rule 0
[111] Logic rule 1
[112] Logic rule 2
[113] Logic rule 3
[114] Logic rule 4
[115] Logic rule 5
[120] SL Time-out 0
[121] SL Time-out 1
[122] SL Time-out 2
[123] SL Time-out 3
[124] SL Time-out 4
[125] SL Time-out 5
13-10 Comparator Operand
Array [6]
Option: Function:
[126] SL Time-out 6
[127] SL Time-out 7
[130] Digital input
DI18
[131] Digital input
DI19
[132] Digital input
DI27
[133] Digital input
DI29
[134] Digital input
DI32
[135] Digital input
DI33
[150] SL digital
output A
[151] SL digital
output B
[152] SL digital
output C
[153] SL digital
output D
[154] SL digital
output E
[155] SL digital
output F
[160] Relay 1
[161] Relay 2
[180] Local
referecnce
active
[181] Remote
reference
active
[182] Start
command
[183] Drive stopped
[185] Drive in hand
mode
[186] Drive in auto
mode
[187] Start
command
given
[190] Digital input
x30/2
[191] Digital input
x30/3
[192] Digital input
x30/4
[205] No Flow
[206] Dry Pump
Parameter Descriptions Programming Guide
M0010001 Danfoss A/S © 10/2019 All rights reserved. 131
3 3

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
CategoryDC Drives
ModelDanfoss VLT FC 102
Output voltage range0 to rated motor voltage
Power range0.37 kW to 200 kW
Communication interfacesRS-485
Protection featuresOvervoltage, undervoltage, overcurrent, short circuit, earth fault, overtemperature, motor thermal protection
Cooling methodAir-cooled
Enclosure ratingIP20, IP21, IP55 (depending on model)
ApprovalsCE, UL, cUL

Related product manuals