Enclosure size
B1
B2
B3
B4
Height [mm (in)]
Height of mounting plate
A
(1)
480 (18.9)
650 (25.6)
399 (15.7)
520 (20.5)
Height with ground termination
plate for fieldbus cables
A
420 (16.5)
595 (23.4)
Distance between mounting holes
a
454 (17.9)
624 (24.6)
380 (15)
495 (19.5)
Width [mm (in)]
Width of mounting plate
B
242 (9.5)
242 (9.5)
165 (6.5)
230 (9.1)
Width of mounting plate with 1 C
option
B
242 (9.5)
242 (9.5)
205 (8.1)
230 (9.1)
Width of mounting plate with 2 C
options
B
242 (9.5)
242 (9.5)
225 (8.9)
230 (9.1
Distance between mounting holes
b
210 (8.3)
210 (8.3)
140 (5.5)
200 (7.9)
Depth [mm (in)]
Depth without option A/B
C
260 (10.2)
260 (10.2)
249 (9.8)
242 (9.5)
With option A/B
C
260 (10.2)
260 (10.2)
262 (10.3)
242 (9.5)
Screw holes [mm (in)]
c
12 (0.47)
12 (0.47)
8 (0.31)
d
ø19 (ø0.75)
ø19 (ø0.75)
12 (0.47)
e
ø9 (ø0.35)
ø9 (ø0.35)
6.8 (0.27)
8.5 (0.33)
f
9 (0.35)
9 (0.35)
7.9 (0.31)
15 (0.59)
Maximum weight [kg (lb)]
23 (51)
27 (60)
12 (26.5)
23.5 (52)
Front cover tightening torque [Nm (in-lb)]
Plastic cover (low IP)
Click
Click
Click
Click
Metal cover (IP55/66)
2.2 (19.5)
2.2 (19.5)
1
See
Illustration 34 and Illustration 35.
Table 72: Power Ratings, Weight, and Dimensions, Enclosure Size C
Enclosure size
C1
C2
C3
C4
Rated power [kW
(hp)]
200–240 V
18–30 (24–40)
37–45 (50–60)
22–30 (30–40)
37–45 (50–
60)
380-480/500 V
37–55 (50–75)
75–90 (100–125)
45–55 (60–75)
75–90 (100–
125)
525–600 V
37–55 (50–75)
75–90 (100–125)
45–55 (60–75)
75–90 (100–
125)
525–690 V
37–90 (50–125)
45–55 (60–75)
AQ267037536117en-000101 / 130R0083 | 113Danfoss A/S © 2023.09
Specifications
VLT HVAC Drive FC 102
Operating Guide

Table of Contents

Other manuals for Danfoss vlt FC 102

Related product manuals