Type designation
P37K
P45K
P55K
P75K
P90K
Power losses and efficiency
Estimated power loss at rated maximum load [W]
(2)
739
843
1083
1384
1474
Efficiency
(3)
0.98
0.98
0.98
0.98
0.99
1
B3+4 and C3+4 may be converted to IP21 using a conversion kit.
2
The typical power loss is at normal load conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions).
Values are based on a typical motor efficiency. Lower efficiency motors also add to the power loss in the drive and vice versa. If the switching fre-
quency is raised from nominal, the power losses may rise significantly. LCP and typical control card power consumptions are included. Further op-
tions and customer load may add up to 30 W to the losses. (Though typically only 4 W extra for a fully-loaded control card or options for slot A or slot
B, each). Although measurements are made with state-of-the-art equipment, some measurement inaccuracy must be allowed for (±5%).
3
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency.
8.3 Electrical Data, 525–600 V
Table 49: Mains Supply 3x525–600 V AC - Normal Overload 110% for 1 Minute, P1K1–P7K5
Type designation
P1K1
P1K5
P2K2
P3K0
P3K7
P4K0
P5K5
P7K5
Typical shaft output [kW]
1.1
1.5
2.2
3.0
3.7
4.0
5.5
7.5
IP20/UL Open Type
A3
A3
A3
A3
A2
A3
A3
A3
IP21/UL Type 1
A3
A3
A3
A3
A2
A3
A3
A3
IP55/UL Type 12
A5
A5
A5
A5
A5
A5
A5
A5
IP66/UL Type 4X
A5
A5
A5
A5
A5
A5
A5
A5
Output current
Continuous (3x525–550 V) [A]
2.6
2.9
4.1
5.2
6.4
9.5
11.5
Intermittent (3x525–550 V) [A]
2.9
3.2
4.5
5.7
7.0
10.5
12.7
Continuous (3x525–600 V) [A]
2.4
2.7
3.9
4.9
6.1
9.0
11
Intermittent (3x525–600 V) [A]
2.6
3.0
4.3
5.4
6.7
9.9
12.1
Continuous kVA (525 V AC) [kVA]
2.5
2.8
3.9
5.0
6.1
9.0
11
Continuous kVA (575 V AC) [kVA]
2.4
2.7
3.9
4.9
6.1
9.0
11
Maximum input current
Continuous (3x525–600 V) [A]
2.4
2.7
4.1
5.2
5.8
8.6
10.4
Intermittent (3x525–600 V) [A]
2.7
3.0
4.5
5.7
6.4
9.5
11.5
SCCR
A2/A3 with mains disconnect [kA
rms
]
50 kA
50 kA
50 kA
50 kA
50 kA
50 kA
50 kA
50 kA
A4/A5 with mains disconnect [kA
rms
]
65 kA
65 kA
65 kA
65 kA
65 kA
65 kA
65 kA
65 kA
Without mains disconnect [kA
rms
]
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
100 kA
AQ267037536117en-000101 / 130R008390 | Danfoss A/S © 2023.09
Specifications
VLT HVAC Drive FC 102
Operating Guide

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals