Type designation
P11K
P15K
P18K
P22K
P30K
With mains disconnect [kA
rms
]
65 kA
65 kA
65 kA
65 kA
10 kA
Without mains disconnect [kA
rms
]
100 kA
100 kA
100 kA
100 kA
100 kA
Power losses and efficiency
Estimated power loss at rated maximum load [W]
(2)
278
392
465
525
698
Efficiency
(3)
0.98
0.98
0.98
0.98
0.98
1
B3+4 and C3+4 may be converted to IP21 using a conversion kit.
2
The typical power loss is at normal load conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions).
Values are based on a typical motor efficiency. Lower efficiency motors also add to the power loss in the drive and vice versa. If the switching fre-
quency is raised from nominal, the power losses may rise significantly. LCP and typical control card power consumptions are included. Further op-
tions and customer load may add up to 30 W to the losses. (Though typically only 4 W extra for a fully-loaded control card or options for slot A or slot
B, each). Although measurements are made with state-of-the-art equipment, some measurement inaccuracy must be allowed for (±5%).
3
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency.
Table 48: Mains Supply 3x380–480 V AC and 3x220Y/380–277Y/480 V AC, Normal Overload 110% for 1 minute, P37K–P90K
Type designation
P37K
P45K
P55K
P75K
P90K
Typical shaft output [kW]
37
45
55
75
90
Typical shaft output at 460 V [hp]
50
60
75
100
125
IP20/UL Open Type
(1)
B4
C3
C3
C4
C4
IP21/UL Type 1
C1
C1
C1
C2
C2
IP55/UL Type 12
C1
C1
C1
C2
C2
IP66/UL Type 4X
C1
C1
C1
C2
C2
Output current
Continuous (3x380–439 V) [A]
73
90
106
147
177
Intermittent (3x380–439 V) [A]
80.3
99
117
162
195
Continuous (3x440–480 V) [A]
65
80
105
130
160
Intermittent (3x440–480 V) [A]
71.5
88
116
143
176
Continuous kVA (400 V AC) [kVA]
50.6
62.4
73.4
102
123
Continuous kVA (460 V AC) [kVA]
51.8
63.7
83.7
104
128
Maximum input current
Continuous (3x380–439 V) [A]
66
82
96
133
161
Intermittent (3x380–439 V) [A]
72.6
90.2
106
146
177
Continuous (3x440–480 V) [A]
59
73
95
118
145
Intermittent (3x440–480 V) [A]
64.9
80.3
105
130
160
SCCR
With mains disconnect [kA
rms
]
65 kA
65 kA
10 kA
65 kA
65 kA
Without mains disconnect [kA
rms
]
100 kA
100 kA
100 kA
100 kA
100 kA
AQ267037536117en-000101 / 130R0083 | 89Danfoss A/S © 2023.09
Specifications
VLT HVAC Drive FC 102
Operating Guide

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals