AutoLab TF Dispenser Technical Manual – Revision 5
AutoLab TF dispensers Technical Manual TFTMTF / Rev 5.0 / 24
th
May 2006 Page 53 of 150
WIRE
NO.
INPUT BIT NO.
OF LA50B DIO
DESCRIPTION
TYPE OF
SENSOR
EXPLAINATION AutoLab TF-120/160
123 7 / 1 DIO1
B zone
Middle sensor of air
cylinder for water
dispensing head.
Magnetic
Water dispenses head above the dye
pots No. 1, 3 and 5.
124 8 / 1 DIO1
B zone
Back sensor of air
cylinder for water
dispensing head.
Magnetic
Water dispenses head is on back
position.
125 9 / 1 DIO1
B zone
Dye pot type
identification sensor1
Magnetic
126 10 / 1 DIO1
B zone
Dye pot type
identification sensor2
Magnetic
1. Both no sensing, dye pot A.
2. Only sensor 1 sensing, dye pot B.
3. Only sensor 2 sensing, dye pot C.
4. Both sensing, dye pot D.
129 13 / 1 DIO1
B zone
Confirm button
Push
Button
Push the button when to start dispensing,
and it flashing in dispensing